VISTA-20P how to set entry delay

Updated Source: K5305-1PRV9 Rev BAsked 1 time
Quick answer

Set Resideo VISTA-20P Entry Delay #1 in data field *35 .

Steps

From: VISTA-20P/15P Security Systems programming guide, p. 8

  1. Program *35 Entry Delay #1 for Partition 1 and Partition 2
  2. Enter 00–96 for 0–96 seconds, 97 for 120 seconds, 98 for 180 seconds, or 99 for 240 seconds

Specs & limits

From: VISTA-20P/15P Security Systems programming guide, p. 8

NoteShown value is 30 seconds for Partition 1 and Partition 2.
NoteCommon zones use the same delay as Partition 1.
VISTA-20PSIA/VISTA-15PSIASIA minimum is 30 seconds; an entry under 30 becomes 30 seconds. 97 = 120 seconds, 98 = 180 seconds, 99 = 240 seconds.
UL Residential Burglary Alarmmaximum 30 seconds; entry delay plus dial delay should not exceed 1 minute.
UL Commercial Burglar Alarmtotal entry delay may not exceed 45 seconds.

Applies to

VISTA-20P

Sources

  1. VISTA-20P/15P Security Systems Programming Guide, p. 8 (K5305-1PRV9 Rev B)
Was this right?