Ubiquiti UPS-2U-Pro · 1 of 1 · Image: Ubiquiti
| ups-2u-pro-us | ups-2u-pro-us |
No reviews yet.
Distribution
Market
| Type | Line interactive |
|---|---|
| Power | (1) OVC II AC in: NEMA 5‑20P (8) Battery backup/surge protection: NEMA 5‑20R (Outlets are individually resettable) |
| Status | Off: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery |
| Weight | 32 kg (70.5 lb) |
| Buttons | (1) Power (1) Factory reset (1) Circuit breaker |
| Display | 3.7” touchscreen |
| Runtime | Full load: 9 min Half load: 22 min |
| Capacity | 1920VA/1920W |
| Ethernet | True |
| Store SKU | UPS-2U-Pro-US |
| Wave Form | Pure sine wave (Battery mode) |
| Dimensions | 442.4 x 87.4 x 630 mm (17.4 x 3.4 x 24.8") |
| Management | Ethernet |
| Form Factor | Rack mount (2U) |
| Mobile Apps | iOS™: Version 10.36.1 and later Android™: Version 10.39.3 and later |
| Battery Type | (1) Lead Acid 72V, 10Ah |
| Power Method | (1) TN system, 120V AC, 16A Max., 50/60 Hz |
| Transfer Time | 6 ms typical; 10 ms max. (Battery mode) |
| UniFi Network | Version 10.5.67 and later |
| Certifications | FCC, IC, UL 1778, CSA C22.2 No. 107.3 |
| NDAA Compliant | True |
| Output Voltage | 120V AC |
| Frequency Range | AC mode: 50/60 Hz ±5 Hz (Auto sensing) Battery mode: 60 Hz ±1 Hz |
| Weatherproofing | IP20 |
| Enclosure Material | Galvanized steel |
| Operating Altitude | 3,000 m (1.9 mi) |
| Input Voltage Range | 89–145V AC |
| Networking Interface | (1) 100/10 MbE port for network connection (2) GbE ports for surge in/out |
| AC Voltage Regulation | ±1.5% (Battery mode) |
| Battery Charging Time | 8 hours recovery to 90% capacity |
| Nominal Input Voltage | 120V AC |
| Operating Environment | Pollution Degree 2 |
| Nominal Output Voltage | 120V AC |
| Overload at Battery Mode | 103–120% 1 min go to fault 120–150% 10 sec go to fault 150% 0.5 sec go to fault |
| Overload at On-Line Mode | 103–120% 5 min go to fault 120–150% 10 sec go to fault 150% 1 sec go to fault |
| Emergency Power Off (EPO) | True |
| Ambient Operating Humidity | 0 to 95% noncondensing |
| Ambient Storage Temperature | -15 to 50° C (5 to 122° F) |
| Ambient Operating Temperature | 0 to 40° C (32 to 104° F) |
| Short Circuit Protection at On-Line Mode | Breaker, 250V AC, 20A |
No discussions tagged to this part yet.