Handbook › System Designer

System Designer PRO

Lay out a door, auto-wire readers and locks, and export the cable schedule.

See it in action

Trinity Ridge Dental

3 doors · LP1502 + MR52-S3 · Pan, zoom, and hover a cable. Nothing on this layout can be edited.

15 cables · 52 conductors Boards traced from PLT-05244, PLT-05248, Altronix ACM Series Power 2.79 A of 6 A · 46%
100%
Scroll to zoom · drag to pan · hover a cable to trace it

Parts

Cable schedule

IDRunCableLength
C01ACM8 Out 1 → LP1502 TB118/26 ft
C02ACM8 Out 2 → MR52 TB718/28 ft
C03LP1502 TB3 → MR52 TB6Belden 9841 RS-48540 ft
C04LP1502 TB8 → Door 1 Signo 4022/6 shielded85 ft
C08LP1502 TB9 → Door 2 Signo 4022/6 shielded120 ft
C07LP1502 Out 1 → Door 1 strike18/278 ft
C11LP1502 Out 2 → Door 2 strike18/2116 ft
C05LP1502 TB4 → Door 1 contact22/292 ft
C06LP1502 TB4 → Door 1 DS16022/480 ft
C09LP1502 TB5 → Door 2 contact22/2126 ft
C10LP1502 TB5 → Door 2 DS16022/4118 ft
C13MR52 TB1 → Door 3 contact22/264 ft
C14MR52 TB1 → Door 3 DS16022/458 ft
C12MR52 TB8 → Door 3 Signo 40West Penn 3021 18/660 ft
C15MR52 RLY1 → Door 3 strike18/256 ft

Power 2.79 A of 6 A · 46%

Bill of materials

Build your own setup — upgrade to Pro

The device wiring layout is a Pro tool. Pan, zoom, and hover this layout. Inputs, save, and export stay off until you upgrade.

Build your own setup — upgrade to Pro

14-day trial, then $19.99/mo or $199/yr · cancel anytime · See plans