Blue Line Gen2 PIR ISC-BPR2

Flag notes: Saved copy is a distributor mirror (A1 Security Cameras); no boschsecurity.com copy obtained · Exact coverage pattern dimensions not transcribed

Nc alarm loop Alarm plus tamper series
Bosch ISC-BPR2Bosch ISC-BPR2 Nc alarm loop. − connects to Panel aux −. + connects to Panel aux + 9–15 VDC. NC connects to Alarm relay contact (NC pair). NC connects to Alarm relay contact (NC pair). T connects to Tamper contact. T connects to Tamper contact.Bosch ISC-BPR2Nc alarm loopPower−Panel aux −+Panel aux + 9–15 VDCAlarmNCAlarm relay contact (NC pair)NCAlarm relay contact (NC pair)TamperTTamper contactTTamper contact
Bosch ISC-BPR2 Nc alarm loop. − connects to Panel aux −. + connects to Panel aux + 9–15 VDC. NC connects to Alarm relay contact (NC pair). NC connects to Alarm relay contact (NC pair). T connects to Tamper contact. T connects to Tamper contact.

Terminals Flag

TerminalGroupFunctionConnects to
− Power Panel aux − Flag
+ Power Panel aux + 9–15 VDC Flag
NC Alarm Alarm relay contact (NC pair) Flag
NC Alarm Alarm relay contact (NC pair) Flag
T Tamper Tamper contact Flag
T Tamper Tamper contact Flag

Key specs

Power9–15 VDC, 10 mA (0.12 W) @ 12 VDC
Alarm relay≤100 mA, 25 VDC, 2.5 W; <20 Ω closed
Mounting height2.2–2.75 m (7.5–9 ft), 2.2 m recommended
Ul temp0 to +49 °C
StandbyListed source must provide 4 h (40 mAh)
RatingEN 50131-2-2 Grade 2, IP30 IK04
Optional bracketsB328, B338, B335

Use only a Listed limited-power source

Walk test at least once a year

LED enable/disable selector on the board (Step 5 figure)

How to wire it

  1. Connect − to Panel aux −.
  2. Connect + to Panel aux + 9–15 VDC.
  3. Connect NC to Alarm relay contact (NC pair).
  4. Connect NC to Alarm relay contact (NC pair).
  5. Connect T to Tamper contact.
  6. Connect T to Tamper contact.

Source

Blue Line Gen2 PIR Motion Detector ISC-BPR2-W12 Installation Guide · F.01U.139.797 rev 05 (2011.6)

Values from F.01U.139.797 rev 05 (2011.6).

Verify against the manufacturer's install guide.

Open in builder

Related parts

Planning aid only. Values are typical and vary by manufacturer, code edition and jurisdiction. Verify with manufacturer data, NEC/NFPA/TIA and the local AHJ. HireLV is not liable for designs based on these tools.