| Input voltage | 5-16 VDC (12 VDC for RS-485) |
|---|---|
| Standby avg | 60 mA (910N) · 75 mA (910P) · 110 mA (910L) |
| Max avg | 95 mA (910N) · 100 mA (910P) · 135 mA (910L) |
| Peak | 200 mA |
| OSDP module | +40 mA |
| Supply | Listed access control / burglary power-limited supply (UL) |
| Wiegand cable | 500 ft of 22 AWG, or 300 ft of 24 AWG. 5-9 conductors. |
| OSDP cable | 4000 ft bus, 24 AWG, 1640 ft between nodes. 4-conductor twisted pair, overall shield, UL approved (Belden 3107A or equiv) 120 ohm +/-2 ohm across bus ends if >200 ft (61 m) or EMI |
| Operating temp | -30F to 150F (-35C to 65C); BT config -13F to 150F |
| Outdoor | Yes |
| IP rating | Not in guide |
| Read range | Not in guide |
| Dimensions | Not in guide |
| Mounting | Backplate to junction box or wall; Imperial 0.138-32 x 0.375 in screws, metric M3.5 x 12 mm, wall 0.138-20 x 1.5 in; security screw 0.138-32 x 0.375 in (HID tool 04-0001-03) |
| UL 294 | Access control line security I, destructive attack I, endurance IV, standby power I |
| Config | Order code x3=R adds RS-485/OSDP; behaviour changed via purchasable config cards (audio/visual, CSN, keypad output). Guide does not describe a DIP/jumper selector. |
Last verified Oct 17, 2026 · PLT-01579 Rev A.6
Controller terminal names are HireLV generic Mercury-style reader-port labels, not from the HID guide. Map per actual controller. On a Mercury MR52 reader port, OSDP A/B land on the CLK and DAT screws.
The builder sums peak current. OSDP adds the module current from the guide. The supply warns above 80% of its rating.
A published tip earns contributor points. Submitting does not.
No published tips yet.
Sign in to submit a tip.
No related guides yet. Guide library
Other models in this install guide. Not a competitor list.
0 new · 0 from techs · 0 wanted
Shop New · Check price
No tech listings for this part yet.
No wanted posts yet.
Aliases and rough areas only. No exact locations.
0 business listings mention this part.
0 tagged
No discussions tagged to this part yet.
Shop New · Check price
No questions yet. Ask
Outbound links only. HireLV does not host these PDFs. Last checked Oct 17, 2026.