Handbook › Parts › R15

HID

HID R15

iCLASS SE / multiCLASS SE 13.56 MHz contactless readers

/handbook/parts/hid/r15 · HireLV drawing from install-guide facts, not manufacturer artwork.

+ Add to builder

Manufacturer Field photos

No manufacturer photo on file. A field photo can stand in after review.

Manufacturer photos are credited to the vendor. Field photos are real installs, reviewed before they are public, and credited to the uploader. Report a photo. We remove a reported photo within 24 hours.

Add a field photo

Real installs only. EXIF and GPS are stripped. A moderator reviews the photo before it is public. An approved photo is credited to your alias.

Sign in to add a field photo.

Specs

Input voltage5-16 VDC (12 VDC for RS-485)
Standby avg60 mA (910N) · 75 mA (910P) · 110 mA (910L)
Max avg95 mA (910N) · 100 mA (910P) · 135 mA (910L)
Peak200 mA
OSDP module+40 mA
SupplyListed access control / burglary power-limited supply (UL)
Wiegand cable500 ft of 22 AWG, or 300 ft of 24 AWG. 5-9 conductors.
OSDP cable4000 ft bus, 24 AWG, 1640 ft between nodes. 4-conductor twisted pair, overall shield, UL approved (Belden 3107A or equiv) 120 ohm +/-2 ohm across bus ends if >200 ft (61 m) or EMI
Operating temp-30F to 150F (-35C to 65C); BT config -13F to 150F
OutdoorYes
IP ratingNot in guide
Read rangeNot in guide
DimensionsNot in guide
MountingBackplate to junction box or wall; Imperial 0.138-32 x 0.375 in screws, metric M3.5 x 12 mm, wall 0.138-20 x 1.5 in; security screw 0.138-32 x 0.375 in (HID tool 04-0001-03)
UL 294Access control line security I, destructive attack I, endurance IV, standby power I
ConfigOrder code x3=R adds RS-485/OSDP; behaviour changed via purchasable config cards (audio/visual, CSN, keypad output). Guide does not describe a DIP/jumper selector.

Last verified Oct 17, 2026 · PLT-01579 Rev A.6

Wiring

Wiegand OSDP

HID R15 wiegand wiringHireLV drawing from the install-guide wire table. Not manufacturer artwork.Reader leadController label (generic)Red P1-4VO / +12VBlack P1-3GNDGreen P2-3D0 / DATWhite P2-4D1 / CLKOrange P1-2LEDYellow P1-1BZRBrown P1-6cappedBlue P1-7cappedDrain P1-5cappedViolet P2-5cappedRed/Green P2-7cappedTan P2-6cappedPink P2-2cappedGray P2-1capped

Controller terminal names are HireLV generic Mercury-style reader-port labels, not from the HID guide. Map per actual controller. On a Mercury MR52 reader port, OSDP A/B land on the CLK and DAT screws.

Power and cable

The builder sums peak current. OSDP adds the module current from the guide. The supply warns above 80% of its rating.

Tech tips

A published tip earns contributor points. Submitting does not.

No published tips yet.

Sign in to submit a tip.

Troubleshooting

Related guides

No related guides yet. Guide library

Compatible parts

Other models in this install guide. Not a competitor list.

For sale

0 new · 0 from techs · 0 wanted

Shop New

Shop New · Check price

From Techs

No tech listings for this part yet.

Wanted

No wanted posts yet.

Sell yours Post wanted

Aliases and rough areas only. No exact locations.

0 business listings mention this part.

Discussions

0 tagged

No discussions tagged to this part yet.

Start a discussion about this part

Where to buy

Shop New

Shop New · Check price

From Techs

From Techs

Questions

No questions yet. Ask

Documents & links

Outbound links only. HireLV does not host these PDFs. Last checked Oct 17, 2026.

Photo takedown